Description
Marka | Atek |
Measuring range | Diffrent models from 0…100mbar to 0…600Bar r Different vacuum models from 0… -100mbar to 0…-1Bar |
Working Principle | Piezoresistive |
Maximum Pressure Strength | 300%F.S. ≤700mbar, 200%F.S. <250Bar, 150%F.S ≥250Bar *Can be 3 or 5 times. |
Oring – Sealing | Standard NBR, optional FKM(Viton) or EPDM |
Supply Voltage | 4-20 mA: 8 … 32 VDC 0-20 mA: 12 … 30 VDC 0-10 V: 12 … 30 VDC Ratiometric: 5 VDC CANopen: 8…26 VDC |
Current Consumption | 30mA max. |
Output Signal | 4…20mA (2-wire), 0…20mA (3-wire) 0…10VDC, 1…6VDC , 0…5VDC , Ratiometric CANopen |
Accuracy | ±%0,5 F.S @25ᵒC ±%0,3 F.S @25ᵒC |
Response Time | 25ms (standard) … nominal pressure 1ms, 5ms, 125ms (optional) |
Operating Temperature | -40°C…+85°C |
Body Material | Stainless steel body – 1.4305 (AISI303) Optional stainless 316L or Titanium |
Electrical Connection | Socker models DIN43650-A , DIN46350-C , M12 , Packard or PVC cable 3 x 0.14mm2 |
Protection Classı | IP65 or IP67 **If M12 plug-in models use a press-pressed plug cable |
Mounting / Tightening | 15 … 20 Nm |